Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects. Recent ECG foundation models, pre-trained on millions of clinical diagnostic ECG recordings, yet they do not apply directly to wearable devices when the sensor configuration and the task both differ. We present CogAdapt, a framework that adapts a clinical ECG foundation model to wearable cognitive load assessment. CogAdapt has two parts. LeadBridge is a learnable adapter that maps 3-lead wearable signals to a 12-lead-compatible representation. ProFine is a progressive fine-tuning strategy that unfreezes encoder layers in stages while limiting representational drift in the pre-trained model. On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points. The results show that a clinical ECG pretraining can support subject-independent cognitive load assessment from wearable sensors.
CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment
Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects.
- Preview

- Year
- 2026
- Hosting
- Excerpt onlyCC-BY-NC-SA-4.0
Cite
Notes
Only stored in your browser.
Attribution
- Abstract & full text
- arxiv.org/abs/2605.22774CC-BY-NC-SA-4.0
- TL;DR
- Semantic Scholar